|
WATT WARRIOR®
Stop watching a quarter of your lighting bill producing heat not light.
Allowing this just isn't a reasonable business strategy in these times
of ever increasing energy costs.
This is particularly true when an approach, independently certified by
a professional engineer, is available to permanently bring these costs
under control.
So why wait and watch your heat generating lights only cost you more
money?
Saving Energy = Saving Money = Competitive Advantage
|
BENEFITS
|
|
HID costs can be slashed
|
|
ROI less than 2 years |
|
Certified savings of 15 to 25%
|
|
Simple on the ground installation |
|
No aerial fixture change - No
bulb or ballast replacement necessary
|
|
Low initial cost |
|
Up to 20 years of maintenance free savings |
We will perform a cost analysis of your lighting projects and determine
your ROI. This won't cost you anything but will show you that you will
save a lot of money...for 20 or more years!
|
FEATURES
AND ADDITIONAL BENEFITS
|
|
Energy savings (Wattage) of 15
to 25% for both HID lighting
|
|
Return on Investment (ROI) less than 24 months |
|
ROI on lighting panels with mixed
loads up to 70/30 split, HID to Fluorescent
|
|
Lamp and ballast life increases 50 to 75% due to reduced heat at fixture |
|
Reduce maintenance costs because
lamps are lasting longer
|
|
HVAC cooling cost is reduced by lowering indoor lighting heat loads |
|
Harmonics -- Switching occurs
at the conjunction of the 1,3,5 and 7th harmonic for smooth electromechanical
transition from 100% voltages down to a maximum of 50% voltage. This
allows switching without causing surge, spike or harmonics on the power
line. In fact, the Watt Warrior equipment will reduce harmonic disturbances.
|
| Not
a "Wave-Chopper" device, does not create harmonics |
|
Low installation
down time - normal installation is one day with power off 1 to 2 hours
|
|
Compatible with existing energy management systems |
|
Autotransformer burn in time has shown an additional 3% to 10% savings
after 3 mos. of operation |
|
Customer engineered to the individual application |
|
Lighting panels are controlled as a whole by one control unit/autotransformer
combination |
|
Controllers can be linked for facility wide actuation |
|
Must be installed only on circuits with lighting loads |
|
Mixed panels (power and lighting) must be separated with the addition
of a load center |
|
All loads will be identified and balanced prior to installation |
|
Installation audit will reveal
additional electrical savings
|
|
Certified savings by independent licensed electrical engineers |
|
Numerous installations with over 2 years with confirmed results |
|
Reduced CO2, SO2 and NOX emissions |
|
SPECIFICATIONS
|
|
Intended Application
High Intensity Discharge (HID) Fixture/Lamp systems
Mercury Vapor
High Pressure Sodium
Metal Halide
|
|
Works with all existing lighting systems - no fixture replacement necessary |
|
Loads controlled - 10 to 600 amps,
120 to 480 volts, 50 to 60 hz
|
|
Full operation 20 minutes before voltage reduction to complete start
and warm-up |
|
Variable voltage settings (120V
- 480V)
|
|
RS-232 Control interface for lighting level changes and scheduling |
|
Electromechanically controlled
switching with a RS-232 Bus control system
|
| Can
interface with photo, occupancy and timing controls |
|
Fail safe bypass
to 100% full power mode on power failure
|
|
Compatible with existing energy management systems |
|
Timing level changes in 15 minute increments |
|
Controller dimensions (4 sixes based upon application) nominally 30"
x 30' x 8" |
|
Floor or wall mount autotransformer (various sized based upon load) max
footprint of 4' x 4' |
|
Harmonic Generation - NONE / Surges - NONE / Spikes Upon Switching -
NONE |
|
Installation by Factory Trained and Certified Licensed Electricians ONLY |
|
Calibration upon installation |
|
Immediate wattage reduction upon energizing |
|
Equipment service life - Controller
and Autotransformer / 10 to 20 years
|
|
NEMA 1 or 3R Enclosures |
|
Made in USA. All equipment is UL listed. |
Frequently Asked Questions
1. Is your product environmentally
safe?
Environment and clean air are major concerns for us now and in the future.
Installation of Watt Warrior technology to this prevailing type of lighting,
significantly reduces emissions released in the environment because of
reduced electrical energy consumption for our lighting needs.
2. Who can benefit from Watt Warrior?
Some examples are: Auto Dealerships, Gymnasiums, Parking Structures, Bridges
and Tunnels, Warehouse Facilities, Manufacturing Floors, Outdoor Parking,
Sports Facilities, Tennis Courts, Airplane Hangers, Government Facilities.
3. What is the average ROI for the Watt Warrior?
Twenty-four (24) months or less.
4. How does the "estimated annual savings
work"?
We conduct a pre and post analysis of the wattage consumed at the panel.
Based on the information we gather we are able to determine the percentage
of savings a customer will realize.
5. Why do you need to conduct an onsite survey?
In order for us to determine which Watt Warrior Controller(s) is needed
to treat your facility. In addition, this will help us to determine the
calculated savings per the installation.
6. Is your product UL listed?
Yes.
7. Is Watt Warrior patented?
Watt Warrior is a registered trademark and the technology is patented.
8. Can the Watt Warrior treat harmonics?
The Watt Warrior does not add to harmonics, in fact, it reduces any harmonics
found in the overall power system.
9. Can we use your equipment in conjunction with
our EMS (Energy Management System)?
Since we only treat HID and fluorescent lighting, Watt Warrior is an excellent
compliment to any energy management system.
10. What type of guarantee can we expect after
the sale?
We are so confident that our product will help you meet your energy savings
needs that we offer a thirty (30) day money back guarantee. In addition,
we offer a one (1) year warranty on parts and labor and an addition
two (2) years on parts.
Legal Notice
|